[. . . ] 11 / 08 Caution: This product is designed for ceiling installation only. [. . . ] Locate the anchors such that the cables are not vertical but not have angles greater than 20 degrees from the vertical. If suspending from WOOD members a) Drill a 0. 113" (#33 drill bit) diameter hole at the anchor location and twist a Screw Eye into the wood member. If suspending from solid CONCRETE a) Drill a 0. 25" diameter hole 1-3/8" deep at the anchor location. The use of a carbide drill bit manufactured within ANSI B94, 12-77 is recommended. Use a claw hammer to pull the Tie Wire Stud 1/4" to activate the anchor. If suspending from ceiling TRUSS a) Secure the loop end of the Cable to a truss. Insert the loop end of the Cables through the eye of the anchors and pass the opposite end of the cables through the loop end. Insert opposite end of Cable through the rectangular hole in Cable Lock. [. . . ] Use the remaining #10 self-drilling screws to attach the sides of the CPM-ACP to the ceiling grid for stability. [. . . ]